The pig in the picture weighs about 7 kg. An assistant holds the pig across his
lap and at the same time raises the vein. The illustration shows the use of a 22
gauge needle. Sometimes it may help if the finger used to raise the vein gently
pumps the vessel.
Pigs cannot sweat and blood circulation through the ears is important for temperature regulation. In a warm environment the veins are more dilated and blood collection is facilitated.
When the vein has been punctured, the emerging blood can be collected directly by
capillary action into appropriate tubes. This technique is suitable for
measurement of haematocrit and haemoglobin levels, and for making blood smears.
Tubes used to collect blood for haematocrit measurement must be coated with an
anticoagulant. The tubes most often used for haemoglobin measurements (20
microlitres) are not treated in this way. The dilution fluid used for haemoglobin
measurement must therefore be available at hand so that the blood can be blown
into that fluid immediately after collection.
It is possible to undertake intravenous injections using the ear veins even on
newborn piglets. These are held in the same way as was illustrated on the two
previous pictures. Very thin needles, such as 25 gauge, must be used on the very
smallest pigs. The pig on this photograph is larger, and a 23 gauge needle is in
use. The veins are thin-walled and are easily perforated. It can prove
difficult to fasten the syringe to the needle once it is in place in the vein.
The syringe should therefore be fastened to the needle before venepuncture, and
the operator should gently aspirate as the needle is inserted. The operator will
see and feel the needle in the vein. It is a good idea to begin on the peripheral
part of the vein. Then it is possible to try again nearer the head if the first
attempt is unsuccessful.
The needle and ear are fixed between the operator's thumb and forefinger. When
this has been done, the assistant can stop raising the vein and the injection can
begin. For practical reasons, the injection should be performed relatively
quickly, and the amount that can be injected is therefore somewhat limited.
Infusion sets are also commercially available, consisting of a tube connected to a
needle. These 'butterfly needles' must be fastened to the skin using adhesive
tape or a louse. Their great advantage is the flexibility of the tubing. These
sets are available in a variety of sizes, such as 19 and 21 gauge.
This picture shows the central ear vein (the intermediate auricular vein) on a
young sow. The animal has been given azaperone as a sedative. This compound has
the added advantage of causing peripheral vasodilatation, making the vein more
readily accessible.
A venous catheter equipped with a stiletto (Braunule, 18 gauge) has been inserted
into the vein. The stiletto is retained completely within the needle until blood
appears. It is then partially withdrawn and the catheter is inserted into the ear
vein. The catheter illustrated has a 'wing' that aid handling. It may be seen on
the picture between the operator's forefinger and thumb. A similar wing is
mounted on the stiletto. A suitable size catheter for slaughter pigs and young
sows is 18 gauge. On larger sows 16 gauge catheters may be used. This latter
size is also useful on sick animals in urgent need of intravenous fluids.
The catheter has been inserted right up to the wing. It must now be fastened, for
example by a louse. This grasps the end of the catheter at the junction with
the wing and also grips the skin. This method ensures that the catheter remains
in place even if the animal shakes its head relatively violently.
The correct point of venepuncture is illustrated in this picture. The needle
should be directed caudo-dorsally, in this case perpendicular to the skin.
The picture is a close-up view of the neck of the same sow, taken from the side.
The correct puncture site is in the deepest point of the jugular groove formed
between the medial sternocephalic and lateral brachiocephalic muscles. This site
is marked on the picture by a black dot. Right-handed operators will usually find
it easiest to use the animal's right jugular vein.
A vacuum tube has been connected, and the needle inserted in its full length.
This is important, since these needles are really slightly too short for large
sows, and the adipose tissue above the vein must therefore be compressed somewhat.
Blood is seen entering the glass tube.
This picture shows the same situation as in the previous illustration, but the
picture has been taken diagonally from in front. The jugular groove is easily
seen. In order to illustrate the technique as well as possible, the needle holder
is only held in place on this picture and the previous one by the operator's
forefinger. In reality this holder should be held more firmly.
It is vital that the needle holder is held firmly if the operator wishes to change
vacuum tubes. This picture shows a good method of doing this. The blood sample
is being taken in the right external jugular vein. The operator holds the needle
holder with his left hand, at the same time pressing it gently against the sow's
neck. He uses his right hand to change tube.
In pigs weighing less than 50 kg it is an advantage to collect blood further
caudally (and more medially) in the jugular groove, nearer the manubrium.
Depending upon the puncture site, angle and depth of penetration, blood will be
collected from one of the vessels depicted in the previous picture. It is
difficult to say with certainty which vessel is punctured. An assistant can hold
pigs up to about 20 kg on their lap. The assistant holds the forelegs in one
hand, and the animal's head in the other. The manubrium and puncture site are
marked in black.
For pigs of this size it is a good idea to use a syringe and needle. The needle
is fastened and filled with anticoagulant. For piglets, needles of 23 gauge
should be used, while 22 gauge needles can be used on slightly larger pigs. When
the needle has penetrated the skin, the operator should aspirate as he gentlly
pushes the needle forwards. Blood should be apparent after 10-25 mm, depending on
which vessel is punctured. As soon as blood flows into the needle, it should be
held firmly to avoid further movement. The operator can place his hand on the pig
as shown to steady the needle.
This picture shows venepuncture on a smaller pig, photographed from the side. The
pig lies between the assistant's thighs, and only the head and forelimbs are held.
The head must not be stretched too far backwards, as this impairs air flow through
the throat region.
For ease of blood collection, and to avoid problems if the pig is restless, the
needle may be connected to a plastic tube.
Pigs weighing between 20 and 50 kg can either be held on their backs in a 'trough'
or immobilized with a snout rope as shown on the picture. This pig weighs about
40 kg. The manubrium is marked in black.
The cephalic vein can be used for blood collection in newborn piglets and weanling
animals. It will only be possible to withdraw small amounts of blood from animals
weighing less than 10-15 kg. When they weigh 20-50 kg, it is possible, with some
training, to withdraw blood nearly as quickly as with the other methods described
here. The pig is laid on its back in a 'trough'. The forelimbs are extended
backwards and slightly out from the animal. This position allows the vein to
extend in more of a straight line and it becomes more accessible. The vein and
manubrium are marked in black.
For blood sampling a vacuum tube and a 20 gauge needle is used. The needle is
inserted where the vein is most visible. On the picture it has been inserted in a
cranial direction just lateral to the second teat. The vein appears larger in
this photograph because of a small haematoma. The vein fills maximally during
expiration, a wave of blood is often seen as expiration begins. It is often an
advantage to bend the needle slightly at the point where it joins the plastic
needle holder, so that the holder remains above the skin. In this way the
operator avoids sticking too deeply.
Pigs weighing more than 50 kg must be immobilized as described earlier using a
snout rope. The vein is palpated and the skin is punctured at the point where the
vein is felt most clearly. The vacuum tube is then connected and the needle is
carefully moved around until the vein is punctured. The photograph shows a young
sow. The operator is standing on the animal's right side and inserts the needle
rostrally. This is usually considered to be the best position for right-handed
operators. On the animal's left side it is usually easiest to insert the needle
caudally.
This photograph shows an old sow after weaning. The vein is punctured between
the mammary glands. This is where the milk vein is easiest to palpate. The vein
may be hidden by the glands on sows with well-developed udders. In pigs from
about 5 months of age and upwards it has been stated that it is possible, with
training, to obtain enough blood for serological investigations in about 90% of
cases. The technique has the advantage of being relatively easy to learn, and
the operator is slightly further away from the noise source! In some sows it is
possible to collect blood using this technique without any form of immobilization
while they are lying down or standing in their pen.
This photograph shows a close-up of blood collection in the medial caudal vein.
It is difficult to obtain large amounts of blood even in large pigs. The artery
lies right next to the vein, and arterial blood is not uncommonly collected
instead. There is, however, no undue risk in taking blood from this site.
The end of the catheter can be hidden in a small bag sewn onto the skin. The bag
can be opened and closed as required (the bag is homemade). After blood
withdrawal the catheter is rinsed with a heparin solution. The catheter can also
be used for injections or infusions.
The photographs were developed as transparency film and scanned with an Agfa
Duoscan T1200 scanner. The files were converted to jpeg format using the programs
FotoLook and Corel PhotoPaint.
The spiral icon is from The Icon Bank.