First Alternative Method Validated by a Retrospective Weight-of-Evidence Approach to Replace the Draize Eye Test for the Identification of Non-Irritant Substances for a Defined Applicability Domain
Owner/Developer: Alternatives to Animal Experimentation (ALTEX)
Country: | Switzerland |
---|---|
Languages: | English |
Url: | http://www.altex.ch/resources/Altex_1_10_Hartung.PDF |
Description: |
A replacement alternative to the rabbit eye irritation test has been sought for many years. First published in 1944 by FDA toxicologist J. H. Draize, the test, now known as the Draize Eye Test, has been used extensively to assess eye safety. It has also been a focal point for concern regarding its animal use. In 1992, Molecular Devices developed the Cytosensor Microphysiometer (CM) technology, an automated potentiometric online measurement of pH changes in cells, and evaluated it also for chemically induced irritation. The method was included in some of the six major validation studies for eye irritation from 1991-1997. The results for CM were inconclusive as were those from other tests evaluated as stand-alone methods to fully replace the animal test. [...] After a new, comprehensive evaluation of the prior available data, the ECVAM scientific advisory committee (ESAC) has recently accepted the CM as capable of identifying non-irritants for testing limited to water-soluble surfactants and water-soluble surfactant-containing mixtures. This 25-year development is remarkable and instructive in many respectsThe authors see this as opening the door, at last, for an end to the use of animals as a standard requirement for eye irritation. Here, several of the people critically involved in this processes have summarized the important aspects of this history. |
Category: | Publication |
Channel: | Website - Printed |
Audience: | Scientists - Policy-makers - Regulators - Industry - Researchers - Students |
User access: | Open access |
Updating frequency: | 2010 |
Relevance: | Replacement |
Purpose: | Documentation and information |
Technology/Tools: | Alternative test methods (in vitro) |
Fant du det du lette etter?
Ja, jeg fant det! Nei, jeg fant det ikke!Takk for din tilbakemelding! Vær oppmerksom på at vi ikke kan kontakte deg hvis ikke du oppgir din epostadresse.
Hva lette du etter?
Gi oss gjerne en tilbakemelding slik at vi kan forbedre informasjonen på siden. På forhånd takk for hjelpen! Vennligst skriv inn din epostadresse hvis du vil ha et svar.
Kontakt oss gjerne på e-post hvis du har spørsmål.