Prevalidation of the ex-vivo model PCLS for prediction of respiratory toxicity
Owner/Developer: Toxicology in Vitro
Country: | Netherlands |
---|---|
Languages: | English |
Url: | http://www.sciencedirect.com/science/article/pii/S0887233316300066 |
Description: |
In acute inhalation toxicity studies, animals inhale substances at given concentrations. Without additional information, however, appropriate starting concentrations for in-vivo inhalation studies are difficult to estimate. The goal of this project was the prevalidation of precision-cut lung slices (PCLS) as an ex-vivo alternative to reduce the number of animals used in inhalation toxicity studies. According to internationally agreed principles for Prevalidation Studies, the project was conducted in three independent laboratories. The German BfR provided consultancy in validation principles and independent support with biostatistics. In all laboratories, rat PCLS were prepared and exposed to 5 concentrations of 20 industrial chemicals under submerged culture conditions for 1 h. After 23 h post-incubation, toxicity was assessed by measurement of released lactate dehydrogenase and mitochondrial activity. In addition, protein content and pro-inflammatory cytokine IL-1α were measured. For all endpoints IC50 values were calculated if feasible. For each endpoint test acceptance criteria were established. This report provides the final results for all 20 chemicals. More than 900 concentration–response curves were analyzed. Log10[IC50 (μM)], obtained for all assay endpoints, showed best intra- and inter-laboratory consistency for the data obtained by WST-1 and BCA assays. While WST-1 and LDH indicated toxic effects for the majority of substances, only some of the substances induced an increase in extracellular IL-1α. Two prediction models (two-group classification model, prediction of LC50 by IC50) were developed and showed promising results. |
Category: | Publication |
Channel: | Website - Printed |
Audience: | Students - Scientists - Industry - Researchers - Regulators |
User access: | Open access |
Updating frequency: | 2016 |
Relevance: | Reduction |
Purpose: | Method development - Documentation and information - Toxicological and safety evaluation |
Technology/Tools: | Animal testing (in vivo) |
Did you find what you were looking for?
Yes, I found it! No, I did not!Thanks for your feedback! Please note that we cannot reply to you unless you send us an email.
What are you looking for?
We value your feedback so we can improve the information on the page. Please add your email address if you would like a reply. Thank you in advance for your help.!
Please contact us by email if you have any questions.